Thermo-Fit Windows Performance Data – Thermo-Tech Premium Windows & Doors

Replacement Windows Performance Data

The lower the U-Value and the higher the R-Value, the better the window is at reducing inflame loss .

Ultimate High Performance LoĒ³ 366/Argon/i89

double insulate field glass with LoĒ³ 366/Argon on one glass airfoil and i89 on interior surface

Window Style Glass Type U-Value R-Value Solar Heat Gain
no/Grids
Solar Heat Gain
w/Grids
Visible Light
no/Grids
Visible Light
w/Grids
Condensation
Resistance

U.S.Energy Star
Zones no/Grids
U.S. Energy Star
Zones w/Grids
Casement LoĒ³ 366/Argon/i89 .23 4.35 .18 .17 .42 .38 47 All All
Horizontal Sliders LoĒ³ 366/Argon/i89 .25 4.00 .22 .20 .50 .44 44 All All
Single-Hung LoĒ³ 366/Argon/i89 .25 4.00 .21 .19 .50 .44 43 All All
Double-Hung LoĒ³ 366/Argon/i89 .26 3.85 .20 .18 .47 .42 43 All All
Direct-Set Picture
Window
LoĒ³ 366/Argon/i89 .22 4.55 .24 .22 .56 .50 47 All All
Fixed Casement
Picture Window
LoĒ³ 366/Argon/i89 .22 4.55 .21 .19 .50 .44 48 All All
Awning LoĒ³ 366/Argon/i89 .24 4.17 .18 .17 .42 .38 46 All All

Premium High Performance LoĒ³ 366/Argon

double insulate Glass with LoĒ³ 366/Argon on one glass come on

Window Style Glass Type U-Value R-Value Solar Heat Gain
no/Grids
Solar Heat Gain
w/Grids
Visible Light
no/Grids
Visible Light
w/Grids
Condensation
Resistance
U.S.Energy Star
Zones no/Grids
U.S. Energy Star
Zones w/Grids
Casement LoĒ³ 366/Argon .27 3.70 .19 .17 .43 .39 60 All All
Horizontal Sliders LoĒ³ 366/Argon .29 3.45 .22 .20 .51 .46 55 NC, SC, S NC, SC, S
Single-Hung LoĒ³ 366/Argon .29 3.45 .22 .20 .51 .45 55 NC, SC, S NC, SC, S
Double-Hung LoĒ³ 366/Argon .30 3.33 .21 .19 .48 .43 54 NC, SC, S NC, SC, S
Direct-Set Picture
Window
LoĒ³ 366/Argon .27 3.70 .24 .22 .57 .51 58 All All
Fixed Casement
Picture Window
LoĒ³ 366/Argon .26 3.85 .22 .20 .51 .45 60 All All
Awning LoĒ³ 366/Argon .27 3.70 .19 .17 .43 .39 59 All All

High Performance LoĒ² 272/Argon

doubly Insulated Glass with LoĒ² 272/Argon on one glaze open

Window Style Glass Type U-Value R-Value Solar Heat Gain
no/Grids
Solar Heat Gain
w/Grids
Visible Light
no/Grids
Visible Light
w/Grids
Condensation
Resistance
U.S.Energy Star
Zones no/Grids
U.S. Energy Star
Zones w/Grids
Casement LoĒ² 272/Argon .27 3.70 .28 .26 .48 .43 59 N, NC N, NC
Horizontal Sliders LoĒ² 272/Argon .30 3.33 .33 .30 .57 .51 55 NC NC
Single-Hung LoĒ² 272/Argon .30 3.33 .33 .30 .57 .50 54 NC NC
Double-Hung LoĒ² 272/Argon .31 3.23 .31 .28 .54 .48 54
Direct-Set Picture
Window
LoĒ² 272/Argon .27 3.70 .37 .33 .64 .57 58 N, NC N, NC
Fixed Casement
Picture Window
LoĒ² 272/Argon .27 3.70 .33 .30 .56 .50 59 N, NC N, NC
Awning LoĒ² 272/Argon .28 3.57 .28 .26 .48 .43 58 NC NC

All tests conform to NFRC 100, NFRC 200, NFRC 400, NFRC 500 procedures .

Structural Performance Data

Type Size Tested Class/Performance Grade Air Infiltration Water Infiltration Forced Entry
Casement 30 x 72 LC – 50 .03cfm/ft2 12.12 psf Grade 10
XO Horizontal Slider 72 x 48 R – 40 .07cfm/ft2 6.06 psf Grade 10
XOX 3-Lite Horizontal Slider 108 x 60 LC – 30 .09cfm/ft2 4.60 psf Grade 10
Single-Hung 40 x 72 R – 40 .07cfm/ft2 6.06 psf Grade 10
Double-Hung 48 x 72 R – 40 .02cfm/ft2 6.06 psf Grade 10
Direct-Set Picture
Window
72 x 72 LC – 50 .01cfm/ft2 12.12 psf Grade 10
Fixed Casement
Picture Window
72 x 72 LC – 40 .01cfm/ft2 12.12 psf Grade 10
Awning 48 x 39 LC – 40 .03cfm/ft2 12.12 psf Grade 10

The windows and doors described herein meets or exceeds the AAMA/WDMA/CSA101/I.S.2/A440 .